12K THREE PHASE SOLAR HYBRID INVERTER
12KW:
Model:
ZXB01-TPM-123G-EU | 12kW | Three Phase | 3 MPPT | Hybrid Inverter | LV Battery Supported
Description:
Maximum Charge and Discharge Current to 240A
IP65 Indoor & Outdoor Use,Colorful Touch Screen
Supports Parallel Connection of Multiple Batteries
Supports Charging and Discharging in 6 Time Periods
Monitoring & Remote Upgrade with Wifi Module
48V Low Voltage battery, Built-in Transformer for Safe Isolation
100% Three-Phase Unbalanced Output, Each Phase Output up to 50% of Rated Power
Support AC Coupling On-grid, Retrofit On Grid System to Energy Storage Hybrid System
Max.Supports up to 10 Units in Parallel for Both On-grid and Off-grid Operation
Support Storing Energy from Diesel Generator without External Converter
- Overview
- Related Products
Appendix:Three-phase low voltage 6-12KW-single cover-new version-instruction manual-20241104.pdf
Data sheet
Model | ZXB01-TPM-123G-EU | |||||
pv String input | ||||||
Max. DC input Poer (W ) | 15600 | |||||
Rated pV input Voltage(V) | 550 (160-800) | |||||
Start-up Voltage(V) | 160 | |||||
MPPT Voltage Range (V) | 200-650 | |||||
Full Load MPPT voltage Range (V) | 350-650 | |||||
Max. DC input Current(A) | 26+13 | |||||
Max. DC Short Circuit Current(A) | 34+17 | |||||
No.of MPPT Trackers | 2 | |||||
No.of Strings per MPpT Tracker | 2+1 | |||||
Ac input/output Data | ||||||
Rated AC output Power (W) | 12000 | |||||
Max AC Output Power (W) | 13200 | |||||
AC input,output Rated Current(A) | 18.2/17.4 | |||||
Max.AC input/Output Current(A) | 20/19.1 | |||||
Max.Three-phase Unbalanced output Current(A) | 27.3/26.1 | |||||
Max Output short circuit current (A) | 75 | |||||
Max. Continuous AC Passthrough(A) | 45 | |||||
Peak Power (off grid) | 2 times of rated power, 10 S | |||||
Power Factor | 0.8 leading - 0.8 lagging | |||||
0utput Frequency and voltage | 50/60Hz; 3L/N/PE 220/380Vac, 230/400Vac | |||||
Grid Type | Three Phase | |||||
Total Harmonic Distortion (THDi) | <3% | |||||
DC Current injection | <0.5% ln | |||||
Battery | ||||||
Battery Type | Lead-acid or Lithium-ion | |||||
Battery Voltage Range (V) | 40-60 | |||||
Max. Charging Current (A) | 240 | |||||
Max. Discharging Current (A) | 240 | |||||
External Temperature $ensor | Yes | |||||
Charging Curve | 3 Stages / Equalization | |||||
Charging Strategy for Li-lon Battery | Self-adaption to BMS | |||||
Efficiency | ||||||
Max. Efficiency | 97.6% | |||||
Euro Efficiency | 97.0% | |||||
MPPT Efficiency | 99.0% | |||||
Protection | ||||||
Anti-islanding Protection | Yes | |||||
PV String Input Reverse Polarity | Yes | |||||
Insulation Resistor Detection | Yes | |||||
Residual Current Monitoring Unit | Yes | |||||
Output Over Current Protection | Yes | |||||
Output Shorted Protection | Yes | |||||
Output overvoltage protection | Yes | |||||
Photovoltaic input lightning | Yes | |||||
Surge Protection | DC Type III / AC Type III | |||||
Over voltage Category | DC Type II/AC Type III | |||||
Certifications and standards | ||||||
Grid Regulation | IEC61727/62116,EN50549-1 | |||||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
Ceneral Data | ||||||
Operating Temperature Range (°C) | -40-60℃, >45℃ Derating | |||||
Cooling | Smart Cooling | |||||
Noise (dB) | ≤50 dB | |||||
Communication to BMs | RS485; CAN | |||||
Monitoring mode | Wi-Fi+APP | |||||
weight (kg) | 37.5 | |||||
Size (wx H x D mm) | 446W×576H×255D (Excluding Connectors and Brackets) | |||||
Ingress Protection | Ip65 | |||||
Installation Style | Wall-mounted | |||||
Warranty | 5 Years (10 Years Optional) |