All Categories

Grid-tied and off-grid inverter 6KW

6KW Pure Sine Wave MPPT Solar Inverter, 48V DC to 220V AC

This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger, and battery charger to offer uninterruptible power support with portable size.

Its comprehensive LCD offers user-configurable and easy-accessible button operations such as battery charging current.

  • Pure sine wave inverter
  • 120A MPPT solar charger for Max 7000W PV power
  • 300V-500V(Voc) DC wide range input PV voltage
  •  AC/Solar charger priority, battery charging/cut-off voltage, acceptable input voltage based on different applications.
  •  work without a battery, the inverter can generate power from solar panels directly to load appliances
  • Overview
  • Related Products
Appendix:7000W instruction manual4.0.pdf
model AIO 6KW/48V
Photovoltaic side input
Photovoltaic input voltage range 110-450VDC
Maximum input voltage 450VDC
Maximum input power of photovoltaic system 6000W
Maximum photovoltaic charging current 100A
storage battery
pattern Pb/Li
48VDC
Rated input voltage
Direct cell voltage range 46.4-58.8V(Li),
38.4-60V(Pb)
130A
Maximum charging current
Floating impulse voltage 53.5V(Pb),Li batteries are determined by the user
Average charging voltage 56.5V(Pb),Li batteries are determined by the user
equipment protection
Battery overvoltage protection possess
overload protection possess
Short Circuit Protection possess
Over Temperature Protection possess
Basic parameters
Dimensions height/width/depth 350/300/100mm
weight 9.7kg
noise ≤48dB
Use temperature range -20℃∽+55℃
storage temperature -15℃∽+65℃
Use humidity range 0~90%
No condensation
Using altitude ≤6000m
AC side input
rated voltage 230Vac
Voltage range 170-270Vac(UPS),
90-280Vac(APL)
Maximum input voltage 280VAC
Rated input frequency 50Hz/60Hz
(self-adaption )
Frequency range 40-65Hz
Conversion range 10ms(UPS) 20ms(APL)
Maximum AC charging current 60A
Inverter output parameters
rated output capacity 6.6KW
rated output voltage 230VAC/208VAC/
240VAC
Voltage accuracy ±5%
Rated output frequency 50Hz/60Hz
frequency accuracy ±2%
Output waveform distortion rate (THD) ≤3%
(100%Linear Load )
Power factor 1
Maximum efficiency 97.50%
(PV360V@1/2load)
Mixed network output overload current 50A
Off grid carrying capacity 110%<load<150% (±10%): 10s after Alarm shutdown;                      
150%<load<200% (±10%): 5s after Alarm shutdown;                       
200%<load (±10%): Immediate alarm shutdown;            